DATA LOGGER DEBIT AIR DENGAN PROTOKOL M-BUS UNTUK APLIKASI CHILLER

Muhamad Anda Falahuddin, Muhammad Arman, Susilawati S, Wirenda Sekar Ayu

Abstract


The M-bus protocol is one of the communication protocols in the rapidly developing field of measurement. The protocol uses a pair of cables and can communicate with several measurement devices in two directions such as a flowmeter. In the chiller system, water circulation varies depending on the cooling load and set point of operation, consumption (electric power) and chiller efficiency, one of which can be calculated based on logging the flow of water that circulates over time, therefore the water discharge data logger becomes very important. This study aims to examine the water discharge data logger with the M-Bus protocol for chiller applications. The testing device includes a series of bench water meters as flowmeters (which water can be simulated circulated) equipped with an M-Bus pick-up sensor, M-Bus concentrator and logger, and software connected to a computer. Tests carried out with variations in water discharge based on the valve opening as a simulation of cooling load variations and see the results of recording from time to time on a computer. The display can be in the form of tables and graphs.

Full Text:

PDF

References


Ahmad, Muhammad Waseem, et al., (2016), Building energy metering and environmental monitoring – A state-of-the-art review and directions for future research, Energy and Buildings 120.

Frenzel Jr. Louise E., (2016), Handbook of Serial Communication Interface, pp. 77.

Richter, Klaus-Peter (2015), Remote Meter Reading via M-Bus, Energy Management Product Manager, GOSSEN METRAWATT GMBH

Sikora, Axel, (2013), Portable and Flexible Communication Protocol Stacks for Smart Metering Projects, JOURNAL OF ELECTRONIC SCIENCE AND TECHNOLOGY, VOL. 11, NO. 1.

Šťastný Ladislav, et al., (2013), Wireless communications in smart metering, 12th IFAC Conference on Programmable Devices and Embedded Systems.

Stanford III, Herbert W., (2012) HVAC Water Chillers and Cooling Towers, 2nd edition, CRC Press.

Vural, Baycan, et al., (2017), Multi-Interface Meter Concentration Unit to Improve Residential Energy Efficiency Awareness, International Journal of Control Systems and Robotics, pp. 66-72.

Wardoyo, Siswo, et al., (2016), Wireless Data Logger Suhu Multi Channel Menggunakan Labview, Jurnal Nasional Teknik Elektro dan Teknologi Informasi, Vol. 5, No. 2.

Zhang, Dening, et al., (2016), Heating Meter Reading System Based on GPRS and Radio Frequency Technology, Revista de la Facultad de Ingeniería U.C.V., Vol. 31, No. 9, pp. 163-175.




DOI: https://doi.org/10.31884/jtt.v9i2.500

Refbacks

  • There are currently no refbacks.


Copyright (c) 2023 JTT (Jurnal Teknologi Terapan)

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

View Stats

 

 Creative Common Attribution-ShareAlike 4.0 International (CC BY-SA 4.0)