Abstract


The kitchen is a vital area that provides energy sources through food processing for residences. However, the cooking process can also produce pollutants that are harmful to the body. This study aims to investigate the concentration and distribution of contaminants (CO and CO2) generated from the kitchen to all rooms in the house. In addition, Air temperature and velocity are investigated to observe their relationship with the distribution of pollutants. The investigation procedure utilizes a numerical simulation of a dwelling with two different ventilation cases. The simulation results show no significant difference in air velocity between the two cases. While the addition of natural ventilation in the kitchen area can reduce CO and CO2 concentrations throughout the room by 25.8% and 24.9%, respectively. On the other hand, the indoor air temperature can also be reduced by 4.9% with the same treatment. In conclusion, the addition of a window in the kitchen area has a significant impact on reducing temperature and pollutant concentrations all over the room.

Full Text:

PDF

References


Abdullahi, K. L., Delgado-Saborit, J. M. & Harrison, R. M., 2013. Emissions and indoor concentrations of particulate matter and its specific chemical components from cooking: A review. Atmospheric Environment, Volume 71, pp. 260-294.

ANSYS, 2013. ANSYS Fluent Theory Guide. Cannonsburg(Pennsylvania): ANSYS, Inc..

Chen, Z., Xin, J. & Liu, P., 2020. Air quality and thermal comfort analysis of kitchen environment with CFD simulation and experimental calibration. Building and Environment, Volume 172, p. 106691.

Filho, N. A. R. et al., 2021. Air pollution and indoor settings. World Allergy Organization Journal, Volume 14, p. 100499.

Giwa, S. O., Nwaokocha, C. N. & Odufuwa, B. O., 2019. Air pollutants characterization of kitchen microenvironments in southwest Nigeria. Building and Environment, Volume 153, pp. 138-147.

Liu, S. et al., 2020. Improving indoor air quality and thermal comfort in residential kitchens with a new ventilation system. Building and Environment, Volume 180, p. 107016.

Liu, Y. et al., 2021. Numerical investigation on the influence of natural make-up air in Chinese-style residential kitchen on indoor environment in a partitioned household. Sustainable Energy Technologies and Assessments, Volume 46, p. 101244.

Pal, C. L. & Netam, N., 2021. Analysis of temperature and exhaust gases distribution in residential kitchen of LIG house. Materials Today: Proceedings, Volume 44, pp. 3025-3031.

Xie, W. et al., 2022. Exhaust rate for range hood at cooking temperature near the smoke point of edible oil in residential kitchen. Journal of Building Engineering, Volume 45, p. 103545.

Xie, W. et al., 2021. Parametrized design for the integration of range hood and air cleaner in the kitchen. Journal of Building Engineering, Volume 43, p. 102878.

Xu, A., Li, H. & Feng, G., 2017. Numerical Simulation Analysis of Temperature and Pollutant Concentration Diffusion in the Open Kitchen Cooking Area. Procedia Engineering, Volume 205, pp. 1165-1172.

Yu, K.-P.et al., 2015. Indoor air pollution from gas cooking in five Taiwanese families. Building and Environment, Volume 93, pp. 258-266.

Zhang, H., Wang, F., Wang, Y. & Wang, H., 2017. CFD Simulation of Cooking Particle Distribution and Motion. Procedia Engineering, Volume 205, pp. 1800-1806.

Zhang, J. et al., 2021. The performance of different ventilation methods in residential kitchens with different spatial organizations: A literature review. Building and Environment, Volume 201, p. 107990.




DOI: https://doi.org/10.31884/jtt.v8i1.377

Refbacks

  • There are currently no refbacks.


Copyright (c) 2022 JTT (Jurnal Teknologi Terapan)

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

View Stats

 

 Creative Common Attribution-ShareAlike 4.0 International (CC BY-SA 4.0)